A safety line for every fireplace you manage
Plan a building visit
Send the property, the number of fireplaces and how tenants will be told. We reply with a total and a visit plan.
The safety items we check first
In a rental the questions that matter most are about people breathing and sleeping near a fire. So the first lines of every unit sheet cover the hazards, before any note on wear or looks. Only after those do we write about mortar, metal and finish.
- Anything blocking the flue: nests, fallen tile, debris piled on the smoke shelf
- Signs that exhaust comes back into the room, such as soot staining above the opening
- Gaps in the firebox or hearth where an ember could reach wood
- On gas units, the burner flame and any spillage at the vent
- Whether a carbon monoxide alarm is mounted outside the sleeping rooms
What the alarm line means
State law puts carbon monoxide alarms in homes that burn fuel, and in a rental keeping them in place falls to the owner. We do not install alarms. We note whether one is mounted near the bedrooms of each unit we enter, so your file shows it beside the fireplace findings and any gap is easy to close before a tenant moves in.
A fireplace that passed last year can be made unsafe by one season of heavy use or one nesting bird. That is why most managers keep a yearly sheet for each unit rather than a single report from the purchase.
How a building visit runs
We work through the units in an order that suits the tenants' notice and finish each one before moving to the next. Units labelled to stay unlit go to the top of your file with the reason beside them, and a short note is left in the unit so the tenant knows too.
Entry is yours to arrange: a master key, an on-site manager or tenants at home all work. Where a unit cannot be entered, its sheet says so, and that unit goes on a return visit.
Per fireplace fees
Each fireplace is a separate line, so a building's total grows with the count of fireplaces rather than the size of the building.
- Safety check, per fireplace
- $160
- Camera run of one flue where a unit needs it
- $375
- Soot and blockage removal, per flue
- from $405
A camera run or a sweep is added only to the units whose sheet calls for one.
Manager and board questions
Is a yearly safety check enough, or does every unit need a camera?
The per fireplace check suits units in steady use with no history of trouble. A unit that changes hands, had a chimney fire or shows a warning sign on the check gets the camera.
Do tenants get a copy?
The sheets go to you. Whether a tenant sees one is your call; most managers share the line for that tenant's own unit.
Do you fit carbon monoxide alarms?
No. We record whether one is present near the sleeping rooms, so you can arrange the fitting.
Can an HOA board and a managing agent both receive the file?
Yes. List both at booking and each receives the full set of unit sheets.
What happens to a unit marked to stay unlit?
Its sheet says why and what the usual fix is. Where our list has a price for that fix it appears; otherwise a written quote follows. Until then, tell the tenant in writing not to use the fireplace.
Units with fireplaces on your books?
Send the property and the fireplace count through the contact page and we come back with a total and a plan.
Call (949) 879-2610