The frame on the screen, and the fix that follows
Ask for a flue quote
Tell us what the inspection report flagged and who wrote it. We call back to set a visit and prepare the quote.
What the camera showed
Picture the still: a square of orange clay seen from inside, lit by the camera's lamp, with a dark line running up one face where the tile has split. A little higher, two tiles sit out of line, and where mortar should close the joint there is a gap you could slide a coin into. That frame is the most common reason a flue fails a Level 2 in our part of Orange County.
What the image means is plain. A flue tile exists to hold heat and gases inside a smooth, sealed tube. A split or an open joint lets them reach the brick, and on many older houses the brick sits close to wood. Until the flue is fixed the report will say to leave the fireplace unlit.
Flue findings and their usual fixes
Relining is the fix we write up most. A stainless liner sized for the fireplace or appliance goes down the old flue, is fixed at the top and joined at the bottom, and the old tile stays in place around it. The outside of the chimney does not change.
A liner has no figure on our published list because flue height, the shape of the old tile and the appliance all change the materials. Each relining job gets a written quote naming the liner, its length and the work at both ends.
- Split or offset clay tile: usually relined with stainless steel from top to smoke chamber
- No liner at all, brick open to the smoke: relined, since bare brick was never meant to carry exhaust
- Open mortar joints between tiles: relined, or on a short run with few gaps, repaired inside the old tile
- Thick glazed deposits hiding the tile: swept first, then filmed again before a fix is chosen
Items at the top that often travel with a liner
A failed flue is rarely the only line on the report. Rain that came in through an uncovered top often did part of the damage, and a stack sitting across a wide roof slope may be holding water against its uphill face. Those items have set ranges on our list, shown below.
A gas insert is on the list too. Some owners decide that rather than restore an old flue for wood, they would sooner close the opening with a gas unit that brings its own liner. The quote can be written for either path.
Showing the repair to the other side
When the fix is part of a sale, the buyer will want to see it finished. After relining we film the new liner from top to bottom and add those frames to a short follow-up note, sent to everyone on the original report's list.
Set prices for flue-related work
These are the items with a set range. Relining, crown work and damper parts are not on the list and come with their own written quote.
- Tracing water to its entry and stopping it
- $540 to $3,250
- Peaked diverter on the uphill face
- $430 to $975
- Diverter plus fresh metal at every roof joint
- $650 to $1,600
- Closing the opening with a sealed gas heater
- $2,700 to $5,400
- Fresh camera run before the next decision
- $375
- Covered top with mesh over the flue
- Quoted after we measure
Ranges are wide because roof type, chimney height and access differ; your quote names one figure.
Flue repair questions
Can a cracked flue still carry gas logs?
Not safely. Vented gas logs still send exhaust up the flue, and a split tile leaks it the same way. A sealed insert with its own liner is the usual gas route.
Is a new camera run needed after relining?
For a sale, yes; the buyer will want frames of the finished liner. For your own use, the follow-up note is usually enough.
Does relining change how the chimney looks?
From the street, hardly at all. A new top plate and cap sit where the old flue opening was.
Will a liner stop a leak?
No. A liner deals with heat and smoke. Water comes in through the top, the masonry or the roof joint, and those are separate items on the quote.
How do I know which fix my report means?
Send the finding wording from the report through the contact page. We call back, visit, and the quote spells out which flue item it answers.
A flue item on your report?
Send the finding through the contact page and we set a visit and write the quote.
Call (949) 879-2610